This 5 day course incorporates the NetApp Portfolio: Exploring SAN Architectures and Configurations (SANARCH) and Data ONTAP SAN Implementation (SANIMP) courses, which are required as preparation for the NCIE – SAN Certification. Delegates will learn how to differentiate among the three SAN architectures that are available from NetApp: FAS SANs with the Data ONTAP operating system, E-Series SANs, and V-Series SANs and how to connect Windows® and Linux® hosts via Fibre Channel (FC) and iSCSI protocols to NetApp® SANs
Ota yhteyttä
Voit olla meihin yhteydessä ja tiedustella koulutuksistamme täydentämällä yhteystietosi ja koulutuksen nimen oheen.
Kesto
5 päivää
5 päivää
Toimitus
(Online ja paikan päällä)
(Online ja paikan päällä)
Hinta
Hinta pyydettäessä
Hinta pyydettäessä
By the end of this course, you should be able to:
- Describe the three types of SANs that NetApp supports: FAS SANs, E-Series SANs, and V-Series SANs
- Explore the storage architectures for Data ONTAP and SANtricity software
- Examine the basic configuration of a FAS Data ONTAP SAN
- Investigate an E-Series array SAN with SANtricity
- List the supported configurations for a V-Series SAN
- Describe solution scenarios that are better supported on a FAS SAN, an E-Series SAN, or a V-Series SAN
- Define and describe SANs that use FC, FCoE, and iSCSI protocols
- Configure Windows Server 2012, Red Hat® 6.4, and Data ONTAP® systems for iSCSI connectivity
- Configure Windows Server 2012, Red Hat 6.4, and Data ONTAP systems for FC and FCoE connectivity
- Use FC and iSCSI protocols to create and access LUNs from Windows Server 2012 and Red Hat 6.4 systems
- Install and use SnapDrive® for Windows and SnapDrive for Linux software to create LUNs and Snapshot™ LUNs, to restore LUNs from Snapshot copies, and to remove LUNs
- Size, clone, back up, and recover LUNs on Windows Server 2012 and Red Hat 6.4 systems
- Troubleshoot SAN connectivity and performance issues
Architecting SAN on NetApp Storage
- Module 1 NetApp SAN Architectures
- Describe the difference between SAN and NAS
- Explain the SCSI architecture model
- List the NetApp SAN platforms
- Describe the current hardware that is supported in the different types of NetApp SANs
Module 2 NetApp Storage Architectures
- Describe storage architectures and basic configurations for the Data ONTAP operating system and for SANtricity software
- List the management tools for Data ONTAP and SANtricity
- Explain the architectural features of Data ONTAP and SANtricity that contribute to optimized performance for each data workload
- Describe the NetApp flash portfolio
Module 3 FAS and Data ONTAP SANs
- Briefly describe the Data ONTAP dataprotection and disaster-recovery software
- Describe FlexClone LUN technology
- Describe deduplication and compression technologies
- Discuss failover and giveback in FAS SAN environment
- Discuss SAN software and tools
Module 4 FAS SANs Implementation Overview
- List the steps for implementing a SAN on the Data ONTAP operating system
- Describe the Data ONTAP simulator (Simulate ONTAP software)
Module 5 E-Series, EF Series, and SANtricity SANs
- Explain E-Series failover and failback technology
- Describe SANtricity protection features
- Discuss SANtricity efficiency and caching features
- Manage an E-Series array with SANtricity management software
Module 6 E-Series SANs Implementation Overview
- List the steps for implementing a SAN on SANtricity
- Install the SANtricity simulator
Module 7 V-Series and Third-Party SANs
- Provide an overview of NetApp V-Series systems and storage arrays
- Describe how V-Series provides the advantages of Data ONTAP with third-party SANs
- Describe the V-Series supported topologies
- Explain the advantages of using E-Series and V-Series together
Module 8 V-Series SANs Implementation Overview
- Describe the LUN-to-aggregate mapping strategies
- Explain the pathing assignments for different types of storage arrays
- Describe the NetApp recommended best practices for fabric and array maintenance
- Deploy V-Series systems for a typical storage array and verify the high availability of these systems
- Diagram the topology of a V-Series system deployment by using standard Data ONTAP commands
Module 9 NetApp SAN Solutions
- Describe the target workloads for FAS, V-Series, and E-Series platforms
- List FAS and V-Series use cases
- Discuss E-Series use cases
- Help customers decide between FAS, V-Series, and E-Series platforms
- Explain data migration and tools
- Describe basic sizing tools
Lab Exercises
- Lab 2-1 Identify the exercise environment
- Lab 2-2 Log in to the exercise environment
- Lab 4-1 Use netApp OnCommand System Manager to create a SVM for iSCSI
- Lab 4-2 Configure iSCSI sessions on Microsoft Windows Server 2012
- Lab 4-3 Create an iSCSI-attached LUN for Windows
- Lab 4-4 Use an iSCSI-attached LUN in Windows
- Lab 6-1 Launch the SANtricity simulator
- Lab 6-2 Navigate the Enterprise Management and Array Management Windows
- Lab 6-3 Create a RAID 6 Volume Group
- Lab 6-4 Create a volume in a Volume Group
- Lab 6-5 Assign a Hot Spare Disk
- Lab 6-6 Create a Disk Pool
- Lab 6-7 Create a volume on a Disk Pool
- Lab 6-8 Change volume settings
- Lab 6-9 Delete a volume
- Lab 6-10 Define a host
- Lab 8-1 Verify controller support with the Interoperability Matrix Tool
- Lab 8-2 Discover supported connectivity configuration with the Interoperability Matrix Tool
- Lab 8-3 Prepare documentation with the Interoperability Matrix Tool
- Lab 9-1 Design a NetApp solution for the info-r-us scenario
- Lab 9-2 Design an alternate NetApp solution for the info-r-us scenario
Data ONTAP SAN Implementation Module 1 SAN Concepts
- Describe the difference between SAN and NAS
- Explain the SCSI architecture model
- List the NetApp SAN technologies
- Define basic SAN terminology
- List the basic steps for implement a Data ONTAP SAN
- Describe the educational lab environment for this Course
Module 2 Windows IP Connectivity
- Describe multiple path implementation with iSCSI connectivity
- Configure network ports on Windows and NetApp systems
- Identify the node name on Windows and NetApp systems
- Implement and verify multiple path iSCSI connectivity between Windows and NetApp systems
Module 3 Windows LUN
- Discuss LUN access for Windows Server 2012
- Create a LUN by using wizards
- Explore techniques to configure a LUN for Windows Server 2012
- Explain how SnapDrive for Windows simplifies LUN management
Module 4 Linux IP
- Describe multiple path implementation with iSCSI connectivity for Red Hat and NetApp systems
- Configure network ports on Red Hat systems
- Identify the node name on Red Hat systems
- Set up and verify multiple path IP connectivity between Red Hat and NetApp systems
Module 5 Linux LUN Access
- Describe the steps that you take to allow a Red Hat initiator to access a LUN on a storage system
- Review the Data ONTAP LUN configuration steps
- Find and prepare a LUN on a Linux operating system
- Configure multipath I/O on Linux
- Create and protect LUNs by using SnapDrive for UNIX
Module 6 FC Architecture
- Describe the architecture of the FC topology
- Explain the FC initialization process
- Identity the layers in the FC protocol
Module 7 FC Fabrics
- Discuss fabric layouts
- Describe FC switch concepts
- Explain fabric services
- Describe routing in FC switches
- Examine zoning in FC switches
Module 8 Windows FC Connectivity
- Describe multiple path implementation with FC connectivity
- Configure FC ports on Windows and Data ONTAP storage systems
- Use commands and utilities to identify the worldwide node name (WWNN) and worldwide port name (WWPN) on Windows and Data ONTAP storage systems
- Use commands and utilities to examine FC switch Activity
Module 9 Unified Connect
- Describe NetApp Unified Connect
- Examine the FC over Ethernet (FCoE) enabling technologies
- Configure FCoE on a host, a switch, and a NetApp storage system
- Explain how to leverage older FC technologies with FCoE
Module 10 Linux FC
- Describe multiple path implementation with FC connectivity for Red Hat and NetApp systems
- Configure FC ports on Red Hat systems
- Identify the worldwide node name (WWNN) and worldwide port name (WWPN) on Red Hat systems
- Set up and verify multiple path FC connectivity between Red Hat and NetApp systems
Module 11 LUN Provisioning
- Describe how and when a LUN consumes space from its containing volume
- Discuss backup guarantees through NetApp Snapshot reserve
- Discuss the overwrite guarantee for space-reserved LUNs
- Analyze the default LUN configuration and two thinprovisioning Configurations
Module 12 Host Considerations
- Explore the disk structure of popular file systems
- Describe flow-control issues on a host
- Identify techniques for growing and shrinking a LUN
- Discuss copy offload capacities
Module 13 SAN Management
- Perform administrative tasks on FC target ports
- Perform administrative tasks on LUNs
- Discuss LUN protection schemes
Module 14 SAN Troubleshooting
- Explain how to diagnose a problem within a SAN environment
- Review diagnostic tools and techniques for NetApp Data ONTAP software
This course is not an entry-level course. It is designed for individuals who meet the prerequisites and who want to successfully complete the NCIE-SAN exam and professionals who implement SAN solutions that use NetApp storage systems.
Delegates should be certified as a NetApp Data Management Administrator or have completed the following courses:
- SAN Fundamentals on Data ONTAP WBT
AND either:
- Data ONTAP 7-Mode Administration (D7ADM)) or
- Accelerated NCDA Bootcamp 7-mode (ANCDABC87) or
- NA-CDOTDP or
- Clustered Data ONTAP 8.2 Administration
This 5 day course incorporates the NetApp Portfolio: Exploring SAN Architectures and Configurations (SANARCH) and Data ONTAP SAN Implementation (SANIMP) courses, which are required as preparation for the NCIE – SAN Certification. Delegates will learn how to differentiate among the three SAN architectures that are available from NetApp: FAS SANs with the Data ONTAP operating system, E-Series SANs, and V-Series SANs and how to connect Windows® and Linux® hosts via Fibre Channel (FC) and iSCSI protocols to NetApp® SANs
By the end of this course, you should be able to:
- Describe the three types of SANs that NetApp supports: FAS SANs, E-Series SANs, and V-Series SANs
- Explore the storage architectures for Data ONTAP and SANtricity software
- Examine the basic configuration of a FAS Data ONTAP SAN
- Investigate an E-Series array SAN with SANtricity
- List the supported configurations for a V-Series SAN
- Describe solution scenarios that are better supported on a FAS SAN, an E-Series SAN, or a V-Series SAN
- Define and describe SANs that use FC, FCoE, and iSCSI protocols
- Configure Windows Server 2012, Red Hat® 6.4, and Data ONTAP® systems for iSCSI connectivity
- Configure Windows Server 2012, Red Hat 6.4, and Data ONTAP systems for FC and FCoE connectivity
- Use FC and iSCSI protocols to create and access LUNs from Windows Server 2012 and Red Hat 6.4 systems
- Install and use SnapDrive® for Windows and SnapDrive for Linux software to create LUNs and Snapshot™ LUNs, to restore LUNs from Snapshot copies, and to remove LUNs
- Size, clone, back up, and recover LUNs on Windows Server 2012 and Red Hat 6.4 systems
- Troubleshoot SAN connectivity and performance issues
Architecting SAN on NetApp Storage
- Module 1 NetApp SAN Architectures
- Describe the difference between SAN and NAS
- Explain the SCSI architecture model
- List the NetApp SAN platforms
- Describe the current hardware that is supported in the different types of NetApp SANs
Module 2 NetApp Storage Architectures
- Describe storage architectures and basic configurations for the Data ONTAP operating system and for SANtricity software
- List the management tools for Data ONTAP and SANtricity
- Explain the architectural features of Data ONTAP and SANtricity that contribute to optimized performance for each data workload
- Describe the NetApp flash portfolio
Module 3 FAS and Data ONTAP SANs
- Briefly describe the Data ONTAP dataprotection and disaster-recovery software
- Describe FlexClone LUN technology
- Describe deduplication and compression technologies
- Discuss failover and giveback in FAS SAN environment
- Discuss SAN software and tools
Module 4 FAS SANs Implementation Overview
- List the steps for implementing a SAN on the Data ONTAP operating system
- Describe the Data ONTAP simulator (Simulate ONTAP software)
Module 5 E-Series, EF Series, and SANtricity SANs
- Explain E-Series failover and failback technology
- Describe SANtricity protection features
- Discuss SANtricity efficiency and caching features
- Manage an E-Series array with SANtricity management software
Module 6 E-Series SANs Implementation Overview
- List the steps for implementing a SAN on SANtricity
- Install the SANtricity simulator
Module 7 V-Series and Third-Party SANs
- Provide an overview of NetApp V-Series systems and storage arrays
- Describe how V-Series provides the advantages of Data ONTAP with third-party SANs
- Describe the V-Series supported topologies
- Explain the advantages of using E-Series and V-Series together
Module 8 V-Series SANs Implementation Overview
- Describe the LUN-to-aggregate mapping strategies
- Explain the pathing assignments for different types of storage arrays
- Describe the NetApp recommended best practices for fabric and array maintenance
- Deploy V-Series systems for a typical storage array and verify the high availability of these systems
- Diagram the topology of a V-Series system deployment by using standard Data ONTAP commands
Module 9 NetApp SAN Solutions
- Describe the target workloads for FAS, V-Series, and E-Series platforms
- List FAS and V-Series use cases
- Discuss E-Series use cases
- Help customers decide between FAS, V-Series, and E-Series platforms
- Explain data migration and tools
- Describe basic sizing tools
Lab Exercises
- Lab 2-1 Identify the exercise environment
- Lab 2-2 Log in to the exercise environment
- Lab 4-1 Use netApp OnCommand System Manager to create a SVM for iSCSI
- Lab 4-2 Configure iSCSI sessions on Microsoft Windows Server 2012
- Lab 4-3 Create an iSCSI-attached LUN for Windows
- Lab 4-4 Use an iSCSI-attached LUN in Windows
- Lab 6-1 Launch the SANtricity simulator
- Lab 6-2 Navigate the Enterprise Management and Array Management Windows
- Lab 6-3 Create a RAID 6 Volume Group
- Lab 6-4 Create a volume in a Volume Group
- Lab 6-5 Assign a Hot Spare Disk
- Lab 6-6 Create a Disk Pool
- Lab 6-7 Create a volume on a Disk Pool
- Lab 6-8 Change volume settings
- Lab 6-9 Delete a volume
- Lab 6-10 Define a host
- Lab 8-1 Verify controller support with the Interoperability Matrix Tool
- Lab 8-2 Discover supported connectivity configuration with the Interoperability Matrix Tool
- Lab 8-3 Prepare documentation with the Interoperability Matrix Tool
- Lab 9-1 Design a NetApp solution for the info-r-us scenario
- Lab 9-2 Design an alternate NetApp solution for the info-r-us scenario
Data ONTAP SAN Implementation Module 1 SAN Concepts
- Describe the difference between SAN and NAS
- Explain the SCSI architecture model
- List the NetApp SAN technologies
- Define basic SAN terminology
- List the basic steps for implement a Data ONTAP SAN
- Describe the educational lab environment for this Course
Module 2 Windows IP Connectivity
- Describe multiple path implementation with iSCSI connectivity
- Configure network ports on Windows and NetApp systems
- Identify the node name on Windows and NetApp systems
- Implement and verify multiple path iSCSI connectivity between Windows and NetApp systems
Module 3 Windows LUN
- Discuss LUN access for Windows Server 2012
- Create a LUN by using wizards
- Explore techniques to configure a LUN for Windows Server 2012
- Explain how SnapDrive for Windows simplifies LUN management
Module 4 Linux IP
- Describe multiple path implementation with iSCSI connectivity for Red Hat and NetApp systems
- Configure network ports on Red Hat systems
- Identify the node name on Red Hat systems
- Set up and verify multiple path IP connectivity between Red Hat and NetApp systems
Module 5 Linux LUN Access
- Describe the steps that you take to allow a Red Hat initiator to access a LUN on a storage system
- Review the Data ONTAP LUN configuration steps
- Find and prepare a LUN on a Linux operating system
- Configure multipath I/O on Linux
- Create and protect LUNs by using SnapDrive for UNIX
Module 6 FC Architecture
- Describe the architecture of the FC topology
- Explain the FC initialization process
- Identity the layers in the FC protocol
Module 7 FC Fabrics
- Discuss fabric layouts
- Describe FC switch concepts
- Explain fabric services
- Describe routing in FC switches
- Examine zoning in FC switches
Module 8 Windows FC Connectivity
- Describe multiple path implementation with FC connectivity
- Configure FC ports on Windows and Data ONTAP storage systems
- Use commands and utilities to identify the worldwide node name (WWNN) and worldwide port name (WWPN) on Windows and Data ONTAP storage systems
- Use commands and utilities to examine FC switch Activity
Module 9 Unified Connect
- Describe NetApp Unified Connect
- Examine the FC over Ethernet (FCoE) enabling technologies
- Configure FCoE on a host, a switch, and a NetApp storage system
- Explain how to leverage older FC technologies with FCoE
Module 10 Linux FC
- Describe multiple path implementation with FC connectivity for Red Hat and NetApp systems
- Configure FC ports on Red Hat systems
- Identify the worldwide node name (WWNN) and worldwide port name (WWPN) on Red Hat systems
- Set up and verify multiple path FC connectivity between Red Hat and NetApp systems
Module 11 LUN Provisioning
- Describe how and when a LUN consumes space from its containing volume
- Discuss backup guarantees through NetApp Snapshot reserve
- Discuss the overwrite guarantee for space-reserved LUNs
- Analyze the default LUN configuration and two thinprovisioning Configurations
Module 12 Host Considerations
- Explore the disk structure of popular file systems
- Describe flow-control issues on a host
- Identify techniques for growing and shrinking a LUN
- Discuss copy offload capacities
Module 13 SAN Management
- Perform administrative tasks on FC target ports
- Perform administrative tasks on LUNs
- Discuss LUN protection schemes
Module 14 SAN Troubleshooting
- Explain how to diagnose a problem within a SAN environment
- Review diagnostic tools and techniques for NetApp Data ONTAP software
This course is not an entry-level course. It is designed for individuals who meet the prerequisites and who want to successfully complete the NCIE-SAN exam and professionals who implement SAN solutions that use NetApp storage systems.
Delegates should be certified as a NetApp Data Management Administrator or have completed the following courses:
- SAN Fundamentals on Data ONTAP WBT
AND either:
- Data ONTAP 7-Mode Administration (D7ADM)) or
- Accelerated NCDA Bootcamp 7-mode (ANCDABC87) or
- NA-CDOTDP or
- Clustered Data ONTAP 8.2 Administration
- ` Päivämäärä pyynnöstä